Regenerator module REG-F
Scopes
Technical parameters
Scopes
- Regeneration and branching of the line signal in 3 directions (“cross”);
- Adding/dropping the necessary channel intervals with different interface terminations;
- The built-in cross-connect, which allows switching a E1 stream at 64 kbps channel intervals, organizing conference channels, logical conjunction channels, synchronization tracking, etc.;
- Synchronization - internal or from any port E1;
- The built-in controller;
- Built-in sensors for external object monitoring;
- The embedded regenerator station node;
- Modes of signal transreceiving via one copper cable or separation of receive and transmission signals via different cables;
- Remote and local management;
- Access to the service communication channel.
Technical parameters
Number of line signal directions | 4 |
Regenerator spacing for copper cables | up to 25 km |
Regenerator spacing for optical fiber cables | 40 to 120 km |
Number of conference groups | 30 |
Number of conference group parties | 5 |
Number of logical conjunction groups | 30 |
Number of conjunction group parties | 5 |
Control channel
Interface | RS-232 |
Tools | dedicated software TWS V.2 |
Power supply
Power consumption | 6,4...15,3 W |
Remote power supply of a non-radio-equipped REG-F | |
---|---|
Dropped RPS voltage | 40/65/90 V |
Remote power supply current | 160...170 mА |
Local power supply of a non-radio-equipped REG-F | |
External power supply/ mains voltage | 24 to 48 V/ 220 V |
Power supply of radio repeater URR-P | |
Dropped remote power supply voltage | 40 V |
External local power supply/mains voltage | 12 V, 40 V, 65 V, 90 V |
Design
Corrosion-resistant waterproof case, HxWxD | 700x350x170 mm |
Degree of protection | IP-65 |
Weight, maximum | 31 kg |